New Users to Gemini-2 Controller PLEASE start
first, by going down the menu list provided by clicking on the "Start Here" menu button above this message. |
Frequently Asked Questions about Gemini 2 |
Click on questions to go to answer |
1. Warning about changing battery or adding an external power pack to Gemini-2 |
2. What is the difference between the older and newer versions of Gemini-2 |
3. What do you do if you have two or more Gemini-2 controllers on your network |
4. What are the power requirements for Gemini-2 and the power connector sizes |
5. Can a USB to Wireless Ethernet adapter or a USB bluetooth adapter be plugged into the USB-B/USB-A ports of Gemini-2 to give Wired or Wireless Ethernet capability |
6. Can SkySafari be used with WiFi |
7. Can the hand controller firmware be updated from the main Gemini-2 unit |
8. Can the hand controller Catalogs and logo file be updated from the main Gemini-2 unit |
9. Why are there so many different ways of updating the firmware in the main Gemini-2 unit |
10. What are the Catalogs, EN, DE, ES, FR, HCFirmware, MHC, CONFIG, PEC, HC and Logs sub-directories of the SDcard |
11. What size micro-SDcards can be used in the Gemini-2 main unit and hand controller |
12. Why do two different models have to be built, one for the east side and another for the west side |
13. How do you get Windows 2000, XP, Vista & Win7 to show all the com ports that have been allocated |
14. How to wire the guide cable from a ShoeStringAstronomy GPUSB to Gemini 2 or Gemini 1 |
15. Does Modeling helps to provide better tracking |
16. What setting are needed for the Southern Hemisphere |
17. Info from Craig Stark about PHD and Guiding with the Gemini-II (because Dec input pulses below 75msec might be missed. This limitation has no effect on RA guiding |
18. What is the CWD (Counterweight down position, and how do you determine it |
19. What causes the hand controller to just change languages all of a sudden |
20. What units of measurement are the Index Error, Polar Axis Misalignment, Orthogonally and Flexure measured in |
21. What type of Battery do the Gemini 1 and Gemini-2 units use |
22. What catalogs are included into the hand controller by default. How are more catalogs added to the hand controller |
23. What does the message "Autoguider Error" mean |
24. How to use Windows Problem Steps Recorder |
25. Long RJ12 6P6C cables for Gemini hand controller |
26. How to install unsigned drivers in Win 8 |
27. How to Add a second Ethernet port to a Laptop |
28. Can a model be built using plate solving |
29. Can a Ethernet connection be used without the internet being available |
30. Difference in Admin Privilege in Win 7 and Win 8 |
31. Windows 10 Shortcut keys |
Answers |
1. Warning about changing battery or adding an external power pack to Gemini-2 |
Answer:
WARNING: The Battery circuit in Gemini-2 is much different than in Gemini-1. The battery connects through a small .2v Zener diode directly into the ARM processor. The Data sheet LPC2388.pdf states Vi(VBAT), the separate input for the RTC and the SRAM, has to have 2.0V at minimum, typical 3.3V and 3.6V at max for operation. With the Zener diode inline, that means that a battery voltage between 2.2V and not exceeding 3.8V would be acceptable. A note states that the RTC typically fails at 1.6V (1.8V at the battery). This means that connecting an external Battery pack in place of the internal 3.3V battery will probably damage the ARM processor, So, DON'T DO IT! After replacing the battery, power on Gemini-2 and set the time and date. Failure to do so could cause the processor to draw too much power from the battery and might result in processor damage. You can also save all your setting using the Web interface Firmware/SRAM page "Store SRAM" content to a file before removing the battery, and then "Load SRAM" content from file to restore all the setting after you replace the battery. This will not set the date and time, you still must do this! Here is a video showing how to change the CR2350 battery. Here is a video showing how to change the CR2450 battery in Gemini-2 Mini. When Losmandy receives the circuit boards, the battery has a piece of insulating material inserted between the positive contact and the battery to keep it from powering the ARM processor. What Losmandy does first, is to power up Gemini-2, set the time and date, then pull out the the insulation. This way, the ARM processor does not have a chance to pull excessive current. You can emulate that on the original Gemini-2 version by putting a small piece of plastic or paper on top of the new battery before putting it in. Then power up Gemini-2, set the date and time and remove the insulation. |
2. What is the difference between the older and newer versions of Gemini-2 |
Answer:
|
3. What do you do if you have two or more Gemini-2 controllers on the your network |
Answer: Gemini-2 has a default IP address of 192.168.0.111, and a default MAC address of 1e:30:6c:a2:45:5f. These are set by the firmware an are changeable. If you have more than one Gemini-2 on a local network, you will have to change both the IP address and MAC address in the second one. If you have more than 2 then change the others, as well. You can change the last digit of the MAC address. The MAC address of a Gemini-2 can be anything between 0 and F (Hex for 16). It is also best to use static IP to be safe, so turn off DHCP by unchecking it's box. Do this by going to http://current IP address of Gemini-2 you are going to change/network.cgi Example would be http://192.168.0.111/network.cgi and changing the IP address to 192.168.0.110 in both Current Setting and Stored Setting boxes, then uncheck the DHCP box and also change the MAC address from 1e:30:6c:a2:45:5f to 1e:30:6c:a2:45:5e etc. Change both the Current Setting and the Stored Setting and then hit "Set". When you do this, you will have to reopen the browser page by putting in the new IP address. It can also be done on the hand controller, but that does not set the default IP address, just the current IP address. Also if you are using ASCOM Gemini.net driver, it can only address one mount per computer at a time. You will have to have multiple computers with the ASCOM Gemini.net driver on each, and the Ethernet IP address set correctly and DHCP turned off, or change the IP address configured in Gemini.net each time you want to connect to a different controller. On a local network you cannot have any two devices using the same IP address. If you also change the MAC address, if by some chance you do use DHCP, then the router will automatically assign a different IP address to each Gemini-2. You can see instructions on how to do this. After making these changes you can store these settings to the Micro-SDcard by going to http://IP address of the unit you are working on/firmware.cgi and hitting Store SRAM. The example page is here. It can also be stored in the latest version 1.20 or newer of the hand controller using the Menu-->System-->"STORE" button. |
4. What are the power requirements for Gemini-2 and the power connector sizes |
Answer: Gemini-2 original has two barrel connector inputs (Gemini-2 Mini only has one) much like what is used on laptop computers. The outside diameter is 5.5mm and the inside diameter is 2.1mm. Gemini-2 is designed to be able to provide a absolute maximum of 2.8 amps to each motor. The Gemini-2 is fused at 5 amps on the inputs. Gemini-2 is not designed to function on voltage less than +12 volts and can work all the way up to +18 volts safely. I recommend at least a +5 amp 12 volt switching power supply. The reason for the 5 amps is that some power supplies will drop the voltage below it's rating when higher amperage is required, like slewing. This needs to be a good quality power supply, and many of the lower cost units puts out a lot of voltage spikes and are not well regulated. You have invested $1000.00 in Gemini-2, so don't skimp on the power supply. I personally use a 16V 7 Amp medical rated power supply. Sorry they are not made anymore as it was quite reasonable at $80.00 and has performed quite well for both my Gemini-1 unit and now my Gemini-2 unit. The 16 volts seems to be a sweet spot where both the G1 and G2 works well at. A very similar unit by the same company but at 15V at 6.67 amps is here. |
5. Can a USB to Wireless Ethernet adapter, or a USB bluetooth adapter be plugged into the USB-B/USB-A ports of Gemini 2 to give wired or wireless Ethernet capability. |
Answer: The simple answer is No. Almost all USB dongles where they are WiFi, or BlueTooth, are slave devices, and requires the device that they are being plugged into to: 1. recognize it, and 2. configure them. The Gemini 2 does not have the firmware (smarts) to do this Yet. There is no way to load a driver into the Gemini 2, like you can a PC. This may, however, change in the future. |
6. Can SkySafari be used with Gemini-2 Answer: Yes it can. |
At this time you will need to use two free
programs to insure that it can. The first is the ASCOM
Gemini.net driver and the second is what is called
WiFi Scope. WiFi Scope is a free program, but they do ask for a
donation. Using both together will allow SkySafari to connect
through WiFi Scope to the ASCOM Gemini.net driver into Gemini-2
and control it. SkySafari runs on an
Iphone/Ipad or an
Android device. WiFi Scope is a PC application. Once you have an Ethernet connection with the Gemini, using either the Netgear or D-Link Bridges above, (or a wired connection) then connect WiFi scope to Gemini-2 (Ascom connection) first, and then SkySafari to WiFi scope. There is a small (or maybe larger) problem with SkySafari when using it with Ethernet. It opens up a new socket for each command it sends to Gemini-2. This can eventually overload Gemini-2 ethernet stack. This does not happen when using SkySafari with a serial port. |
7. Can the hand controller firmware be updated from the main Gemini-2 unit |
Answer: Yes. Any file that is placed into the SDcard HCFirmware sub-directory will be uploaded to the Hand controller on the next power on of the Hand Controller. If this file is gemhc.bin it is considered a firmware update, and the hand controller should upload it and and use it as a firmware update. You may have noticed that I said should. There is a problem, in that if the Main Gemini 2 unit has not been booted, and sitting at the Boot menu asking how you want to boot, then the gemhc.bin file will not be used as a firmware update, but as a Catalog file. You must go through the boot menu for this to work correctly. See Question 6. |
8. Can the hand controller Catalogs and logo file be updated from the main Gemini-2 unit |
Answer: Yes. Any file that is placed into the SDcard HCFirmware sub-directory will be uploaded to the Hand controller on the next power on of the Hand Controller. If this file is a catalog file ending in .guc then the hand controller will put it in it's catalog directory, and you will be able to see them with the Go-To command. If the file is the GemLogo.b16 file then the hand controller will place it correctly, so that it shows up during power up of the hand controller, as the boot up logo. If the file is gemhc.bin firmware update, then it will be uploaded to the root of the micro SDcard in the hand controller, and then flashed as an updated firmware. See HC Flashing Example. There are 2 ways to get the Gemini Hand controller to upload files. 1) power it off and then on. 2) Under the MENU -->HC--SDcard menu is a selection that says Upload files. This will also cause the Hand controller to up load catalogs (*.guc) files. NOTE #2 is only for uploading catalog files. It will not work for uploading a firmware update. |
9. Why are there so many different ways of updating the firmware in the main Gemini-2 unit? |
Answer: That is a good question. However the answer is a little complex. To update the firmware, the basic idea is to place a programming file at the root of the Main Gemini-2 unit SDcard. If this file is named "HGM_Gem2.bin", then Gemini-2 will reprogram itself on the next power up and rename the file "Cur_Gem2.bin". After programming this Cur_Gem2.bin file can be deleted with no harm. If the file is named "NewGem.bin", then the web interface has to be used to tell Gemini-2 to use this file and flash the program. The file will not be renamed. After programming this file can be deleted with no harm. The differences are primarily in the method that you use to get one of these two files to the root of the SDcard. There are basically 5 ways:
Note: There are no differences in the NewGem.bin file and the HGM_Cur2.bin file except the file name. You can convert one to the other just by renaming it. |
10. What are the Catalogs, EN, DE, ES, FR, HCFirmware, MHC, CONFIG, PEC, HC and Logs sub-directories of the SDcard |
Answer: These directories are mainly to support different languages. The exception are
|
11. What size micro-SDcards can be used in Gemini-2 main unit and hand controller |
Answer: The micro-SDcards supplied by Losmandy are 2GB cards for both the main unit and hand controller. This might have changed now with Gemini-2 Mini, as 2GB cards are almost impossible to find. Both SD and SDHC types are supported. Use the default Fat size for the 2Gbyte size of micro-SDcards to format them. I have tested up to 32GB cards and they worked. Now this is only true with the latest 5.1 firmware (or later) versions of the firmware. If using 4GB or larger micro-SDcards, they must be formatted using Fat32. The default under Windows 7 is FAT64, do not use that size to format the micro-SDcards, as it will not work Instructions for removing and replacing the micro-SDcards are here. |
12. Why do two different models have to be built, one for the east side and another for the west side |
Answer: After many tried to incorporate one model for both sides of the meridian, it was determined that this caused large model errors after doing a meridian flip. This lead to the development of separate models for each side of the meridian. This of course has the disadvantage that you have to build two distinct models. But it also has many advantages, in that the model can be more accurate and that non-perpendicularities, flexure, and mirror flop can be better compensated for. See Alignment Procedures for more detail. |
13. How do you get Windows 2000, XP, Vista & Win7 to show all the com ports that have been allocated |
Answer: Windows does not normally show non-connected devices in device manager. This is even true if you turn on show hidden devices under the view tab. Before you do this change, be for warned - that this will let you modify/delete devices that you might not want changed or deleted. You do this at your own risk! With that said here is a step by step process.
For 2000 and XP:
The trick was to open the Command Prompt as administrator and start the Device Manager from the same command prompt.
Now if you expand the section on COM ports, all the COM ports that have ever been created will be displayed, the non present ones being in grey. You can uninstall away anything that you don’t want (right click, select uninstall). Also there is a USB port scanner that will tell you every USB port and it's assignment. See http://gemini-2.com/downloads/USB_View/usbdeview.zip |
14. How to wire the guide cable from a ShoeStringAstronomy GPUSB to Gemini 2 or Gemini 1 |
Answer: Here is a link to a wiring diagram provided with the permission if ShoeStringAstronomy that tells how to make the cable that goes from the GPUSB or GPUSB-AH into Gemini-2 or Gemini-1. Note that only the GPUSB is compatible with Gemini-2, or Gemini-1 with round motor cables. Here is the link to the guide_port_cables.pdf. |
15. Does Modeling help to provide better tracking |
Answer: Nope this is wrong. Modeling only helps provide for better GO-TO's. The only thing that really helps accurate tracking is an excellent Polar alignment. If your polar alignment is dead on, and your time, time zone offset, latitude and longitude are dead on, then the G2 should provide accurate tracking, but of course other factors such as gear slop, mount imperfections, balance imperfections, and atmospheric refraction can cause tracking errors, so you might not see perfect tracking, even if you have a perfect polar alignment. |
16. What setting are needed for the Southern Hemisphere |
Answer: The only setting for the Southern Hemisphere is to make sure your Latitude is negative. Gemini-2 will make all the correct setting for the Southern Hemisphere. There are no switches to find or to set. |
17. Info from Craig Stark about PHD and Guiding with Gemini-2. This limitation has no effect on RA guiding |
Answer: Here's what people can do:
|
18. What is the CWD (Counterweight down position, and how do you determine it |
Answer: The CWD down position is when the counterweights are positioned down towards the ground, where the counterweight shaft is as vertical as possible. The Dec axis is also positioned pointing to either the North Pole in the Northern Hemisphere or the South pole in the southern Hemisphere. There is also a document put out by Mike Dodd that tells how to determine the "Magic CWD Position" as he calls it. |
19. What causes the hand controller to just change languages all of a sudden |
Answer:
|
20. What units of measurement are the Index Error, Polar Axis Misalignment, Orthogonally and Flexure measured in |
Answer: Arc-Seconds for all of them. Notice the names are referenced to the Web interface Modeling Web page.
|
21. What type of Battery do the Gemini 1 and Gemini-2 units use |
Answer: Gemini-1 used 2 different types of batteries. In units that have a slide switch for power, the battery is a CR-2032. It the newer Gemini-1 units that use a toggle switch for power, the battery is a CR-2354. The battery in the original Gemini-2 (with two power ports) is a CR-2354. This battery powers the Real Time Clock and SRAM. After replacing this battery, you'll need to power up Gemini-2 and then set the time. When setting the time, remember to store setting, or it will not be saved. This is because the processor will drain the battery if this is not done. It is a known flaw that is documented in the data sheet for the processor that is being used in Gemini-2 units. The newer Gemini-2 Mini uses a CR2450 and is easier to change. The above same warning about setting the time and date still holds true. |
22. What catalogs are included into the hand controller by default? How are more catalogs added to the hand controller |
Answer: The catalogs in the Hand controller by default are: BSL.guc, Combined_Constellation_Stars.guc, LBN.guc, LDN.guc, Messier.guc, PN.guc SAO.guc, Sh2.guc, Southern_constellation_Stars.guc, and WDS.guc. If you would like other catalogs in the hand controller, all that is necessary, is to put them into the HCFirmware directory of the Main Gemini-2 units SDcard. They will be uploaded into the hand controller on the next power up. Didier Garriou Gemini Catalogs building site is a good place to start for instructions on building your own catalogs, and installing them into Gemini-2. He also has some very nice catalogs of his own that you can download. |
23. What does the message "Autoguider Error" mean |
Answer: This error message normally means that the Autoguider input is receiving invalid inputs. If the autoguider input receives both a RA+ and RA- input together, or a DEC+ and DEC- input together, these are invalid conditions, and Gemini-1 and Gemini-2 will give this error message. In the past this has mostly been caused by the SBIG brand of cameras when they were powered off and the Gemini is powered on. The most common solution to this is:
|
24. How to use Windows Problem Steps Recorder |
Answer: You can use Problem Steps Recorder to automatically capture the steps you take on a computer, including a text description of where you clicked and a picture of the screen during each click (called a screen shot). Once you capture these steps, you can save them to a file that can be used by a support professional or someone else helping you with a computer problem. The link will take you to a web page that describes how to use it. |
25. Long RJ12 6P6C cables for Gemini hand controller |
Answer: You can use http://www.digikey.com/product-search/en?keywords=AT-C-26-6%2F6%2FB-14%2FR Assmann AT-C-26-6/6/B-14-R |
26. Install Unsigned Drivers in Win 8 |
Answer: You can goto install unsigned drivers in Win 8 for instructions on how to do this. |
27. How to add a second Ethernet port to a Laptop |
Answer: Pluggable Technologies makes a USB to Gigabit Ethernet adapter. This adapter will add a 10/100/1000 Ethernet port your your laptop using a USB 2.0 port. There is also a USB 3.0 to Gigabit Ethernet Adapter available also. With either of these, going to Gemini-2, you can use a normal Ethernet Patch cable. The other port of the Laptop can then connect to your local network. |
28. Can a model be built using plate solving |
Answer: Yes: You can easily use plate solves manually with your choice of plate solving software. To do this, the plate solving software must be able to issue a Sync command to Gemini.net ASCOM Driver. You'll need to set this setting in the Gemini.net ASCOM driver: "Sync performs additional align". Then, each Sync from the plate solve coordinates will add an additional data point to the Gemini model. |
29. Can an Ethernet connection be used without the internet being available |
Answer: Yes. To use an Ethenet connection between Gemini-2 and a Laptop computer, they will more than likely have to use a static IP address, because a router is not present to provide a DHCP address. Use the Configuring Win10, Win7 or XP instructions to configure the computer for a static IP address. The on the Gemini-2's hand controller Network configuration page, uncheck the DHCP checkbox. Now make sure that you have used the same Gateway in both the computer and the hand controller. IE. 192.168.0.1 as an example. Now the IP address of the computer itself MUST BE DIFFERENT than the one selected for Gemini-2 hand controller. As an example use 192.168.0.100 in the computer and 192.168.0.111 in Gemini-2 hand controller. The netmask should be 255.255.255.0 for both. |
30. Difference in Privilege Admin in Win 7 and Win 8 |
Answer: This problem rears it's ugly head when trying to use Windows File Explorer with Windows 8. Windows 8 and 8.1 will not let you turn off UAC. If UAC is turned off in Windows 7, then File Explorer will act as if it had been started in admin mode, and should have full file privileges. Because you cannot use Windows file explorer in full admin mode with Windows 8 or 8.1, you will probably have to use an external FTP program such as FileZilla to access the micro SDcard contents instead of Windows File Explorer. Now if you are using Windows 7 File Explorer and you try to delete a file on the micro SDcard, and get a permissions error, go into the Windows Control Panel\User Accounts and change the UAC to off (lowest setting.) When you finish, please make sure you restore the setting back. |